A basement suite can help pay the mortgage or give family members their own space. But only a permitted suite is safe, insurable and legal to rent. This guide walks through the process in Vancouver and Burnaby and the building code items that decide whether your basement can become a suite.

In short: you need a building permit, plus plumbing and electrical permits. The suite must be separated from the main home by a fire separation, with the right smoke alarms, enough ceiling height and safe exits. Most problems show up in existing basements with low ceilings or small windows, so check those first.

The five steps

1Check zoning2Plan & drawings3Apply for permit4Build & inspect5Final & occupancy
The basic path to a legal suite in Vancouver or Burnaby.
  1. Check zoning. Both cities allow secondary suites in most residential zones. In Burnaby’s R1 zone, one suite is allowed per main home, it counts toward the lot’s unit total, and it must be at least 32.5 m² (about 350 sq ft).
  2. Plan and draw. A designer prepares floor plans showing the suite, fire separation, exits, windows, ventilation and heating.
  3. Apply for the permit. Submit the building permit, then plumbing and electrical permits for the new kitchen, bathroom and wiring.
  4. Build and inspect. The City inspects at key stages, before walls are closed.
  5. Final inspection. Once it passes, the suite is legal.

The fire separation: the most important item

Main homeSecondary suiteOwn entrance · own kitchen · own bathroom Egress SS Fire separation (red line)Interconnected smoke alarms
Section sketch: the suite is separated from the main home by a fire separation (red), with interconnected smoke alarms and a proper exit.

Under the 2024 BC Building Code, the suite and the main home are separated by walls and ceilings with a fire-resistance rating. Burnaby’s suite guide explains the three options: a 45-minute separation if the smoke alarms aren’t interconnected between units; 30 minutes if an extra interconnected photoelectric alarm is installed in each unit; or 15 minutes if all smoke alarms in the house are photoelectric and interconnected. Doors in the separation need the right rating and a self-closer.

Ceiling height, exits and windows

  • Ceiling height: new suites generally need 2.1 m (about 6’11”). For suites in existing houses, the code’s alternate compliance methods allow 1.95 m in the required areas of rooms. Check yours early: lowering a basement floor is expensive.
  • Exits: the suite needs a safe way out, usually its own exterior door.
  • Bedroom windows: bedrooms need a window big enough to escape through, or a door to the outside.
  • Heating and ventilation: shared ductwork has to be handled so smoke can’t spread between units.
Fire stopping installed at a wall penetration
Fire stopping at a penetration. Every pipe, duct or wire that passes through the fire separation has to be sealed.

Common reasons suites fail inspection

  • Gaps in the fire separation around pipes, ducts and pot lights
  • Ceiling height too low in hallways or under beams
  • Bedroom windows too small or too high
  • Smoke alarms not interconnected the way the drawings say
  • Unpermitted electrical or plumbing work hidden behind finished walls

Vancouver and Burnaby differences

Both cities follow the building code for safety items, but zoning, parking and application steps differ. Vancouver has its own building bylaw and a separate process for renovations; Burnaby applies the BC Building Code and its R1 zoning rules. Ask the City which application type fits your project before you draw anything.

Related reading

Please note: This page is general information, not legal, financial or professional advice. The facts, figures, bylaws, fees and code requirements described here were accurate to the best of our knowledge when it was published or last updated. These rules change often and differ from city to city, so some details may have changed since. Before you make decisions, please confirm the current requirements with your city’s planning and building department and with qualified professionals. We’re always happy to help you check what applies to your property.

Want to know if your basement can become a legal suite? We’ll come and check.

Call 604-786-7000Book a Free Site Visit

Sources

Rules and figures change over time. Confirm the current requirements for your property with your municipality and qualified professionals.

Mandeep Singh, Builder and Director at Xerox Builders
Written by
Mandeep Singh
Builder & Director, Xerox Builders Ltd. · BC Housing Licensed Residential Builder

Mandeep has been a licensed residential builder in BC for almost 10 years. He builds custom homes, laneway homes, duplexes and multiplexes in Vancouver, Burnaby, Surrey and Delta, and writes these guides so homeowners know what to expect before they build.

Share This Story, Choose Your Platform!

Recent Works

Tags